B-29, Sector 8, Noida, UP 201301Mon–Sun, 8 am – 7 pm
Request a quote

Quality, testing and certificates

Coating thickness is measured in-house by XRF and reported batch by batch. Adhesion and tarnish resistance are tested on site, and our certificates can be downloaded below.

Thickness measurement by XRF

Coating thickness is the specification buyers check first, so we measure it in-house on a Fischerscope X-RAY XAN, an X-ray fluorescence (XRF) instrument.

Fischerscope X-RAY XAN coating thickness analyser and its computer in the in-house testing lab
Instrument
Fischerscope X-RAY XAN
Lab
Thickness and titration

XRF works by directing a small X-ray beam at the plated surface and reading the radiation the coating gives back. The reading gives the thickness of the coating in µm in a few seconds. The part is not cut, scratched or damaged, so measured parts can still be delivered. The method is described in ISO 3497 and ASTM B568.

Our instrument measures up to three coating layers on a metal base in one reading, for example gold over nickel over copper. We use it on gold, silver, electroless nickel, tin, nickel, tri-metal and copper coatings.

We supply an XRF thickness report with each batch.

XRF testing service

We also test parts and materials that we have not plated. Testing is non-destructive, so parts come back unchanged. It is a paid service, quoted when you enquire.

  • Coating thickness in µm, up to three layers on a metal base
  • Gold carat, the purity of gold items and coatings
  • Metal and alloy composition, for example to check a brass or bronze grade

Ask about XRF testing

Adhesion and other tests

A coating that peels or blisters fails however thick it is. These are the checks we run:

TestWhat it shows
Bend testThe part is bent over a mandrel. The coating must not flake or lift from the base metal.
Tape testAdhesive tape is pressed on and pulled off. No coating may come away with it.
Cross-hatch testA grid is scribed through the coating. The coating must not lift between the lines.
Thermal shockThe part is heated and quenched in cold water. The coating must not blister or flake.
Ammonium sulphide test, IS 1771A drop of dilute ammonium sulphide on anti-tarnish silver must leave no black or brown mark for at least 5 minutes.
Sodium sulphide testAnti-tarnish silver is dipped in a 10% sodium sulphide solution for 3 minutes, then hung in air for 15 minutes. No black spots may appear.

The bend, tape, cross-hatch and thermal shock (heat-quench) methods are described for metallic coatings in ASTM B571 and ISO 2819. Your drawing or customer specification sets which tests apply to your parts.

Bath analysis

Plating baths are analysed by titration in our in-house chemical testing lab, on a fixed schedule, to keep their chemistry within limits.

Management system certificates

  • ISO 9001:2015Quality managementCertificate 139661/A/0001/UK/EnIssued by United Registrar of Systems (URS), UKAS accredited
    Valid to 26 Dec 2027
    Certificate (PDF)
  • ISO 14001:2015Environmental managementCertificate 26DEPO89Issued by ROHS Certification Pvt. Ltd.
    Valid to 28 May 2029
    Certificate (PDF)
  • ISO 45001:2018Occupational health and safetyCertificate 26DOPY80Issued by ROHS Certification Pvt. Ltd.
    Valid to 28 May 2029
    Certificate (PDF)

Each certificate covers our plant at B-29, Sector 8, Noida. Certificates are valid subject to yearly surveillance audits by the certification body.

RoHS and REACH

Our plating services comply with RoHS, and the chemicals we use in plating comply with REACH. Copies are available on request.

Request a quote

Email your drawing for a quote

Attach the drawing and include as much of this list as you can. The more you send, the fewer questions we need to ask before quoting.

Send to [email protected]
  • Drawing: PDF, DWG, DXF or STEP
  • Base material and grade
  • Finish, and thickness in µm
  • Quantity per lot and yearly volume
  • Areas to mask, if any
  • Standard or customer specification
Call Request a quote